Tuesday, 30 September 2014

Export Revit to nwc

Last week I was discussing NWC export settings when I was asked why I set the convert element parameters to all.Truth is that I actually haven't looked into it and I just set it to all because I wanted it all.
So I had a check the other day. Apparently if you set the above export setting Convert Element Parameters to element you don't get Revit type properties. Or at least not where I wanted them. Recently I had spend some time to create searchsets looking for specific assembly codes. These searchsets are looking for: (ignore the dutch words)

selectionset name="28.20_hoofddraagconstructies - wanden en vloeren, algemeen (verzamelniveau)" guid="002812da-1211-2802-3108-151219752812"
            findspec mode="all" disjoint="1"
              conditions
                condition test="equals" flags="10"
                  category
                    name internal="LcRevitData">Revit Type
                  /category
                  property
                    name internal="lcldrevit_parameter_-1002500">Assembly Code
                  /property
                  value
                    data type="wstring">28.20
                  /value
                /condition
              /conditions
              locator>/
           /findspec
          /selectionset

(pretty much all the < and > are removed from the above searchset otherwise it would not show here)

If I don't convert element parameters all these searchsets don't work!

So basically I need to convert all element parameters and properties. It looks like element parameters are Revit's type properties and element properties are Revit's instance properties.
My preferred setting are: